The variable speed drive VSD as ideal method for starting electric induction motors
By programming parameters, implementation of VSD reference CFW-11, and conducting starts with electric induction motors, with different characteristics, we analyze the behavior of the variables: voltage, current, torque and engine velocity to verify that the starting VSD method is the ideal. System...
主要な著者: | , |
---|---|
フォーマット: | Online |
言語: | spa |
出版事項: |
Universidad Pedagógica y Tecnológica de Colombia - UPTC
2013
|
主題: | |
オンライン・アクセス: | https://revistas.uptc.edu.co/index.php/ingenieria_sogamoso/article/view/3414 |
要約: | By programming parameters, implementation of VSD reference CFW-11, and conducting starts with electric induction motors, with different characteristics, we analyze the behavior of the variables: voltage, current, torque and engine velocity to verify that the starting VSD method is the ideal. System graphs are obtained by implementing the tool "Trend" from SuperDriveG2 software, which are analyzed to determine the behavior of the application. |
---|