Control multivariable lineal con desacoples en un intercambiador de calor
Páginas 17-25.
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Artículo de revista |
Language: | spa |
Published: |
Universidad Pedagógica y Tecnológica de Colombia
2017
|
Subjects: | |
Online Access: | https://repositorio.uptc.edu.co/handle/001/1787 |
_version_ | 1801705867768233984 |
---|---|
author | Ricardo Barrera,Jaime Freddy Barrios Urueña, Edgar |
author2 | Universidad Pontificia Bolivariana (Colombia) |
author_facet | Universidad Pontificia Bolivariana (Colombia) Ricardo Barrera,Jaime Freddy Barrios Urueña, Edgar |
author_sort | Ricardo Barrera,Jaime Freddy |
collection | DSpace |
description | Páginas 17-25. |
format | Artículo de revista |
id | repositorio.uptc.edu.co-001-1787 |
institution | Repositorio Institucional UPTC |
language | spa |
publishDate | 2017 |
publisher | Universidad Pedagógica y Tecnológica de Colombia |
record_format | dspace |
spelling | repositorio.uptc.edu.co-001-17872021-02-10T17:32:11Z Control multivariable lineal con desacoples en un intercambiador de calor Linear multivariable control with decoupling in a heat exchanger Ricardo Barrera,Jaime Freddy Barrios Urueña, Edgar Universidad Pontificia Bolivariana (Colombia) Sistemas de control lineal Sistemas de control multivaribales Control de procesos industriales Microprocesadores - Diseño Controladores PI Páginas 17-25. El presente artículo describe la validación de los diseños de control multivariable lineal en un intercambiador de calor bajo ambiente virtual usando Hysys, cuyo interés se centró en analizar las diferentes respuestas del sistema MIMO cuando se realizó el control regulatorio con diferentes desacopladores y sin desacoplador. Se usaron tres tipos de desacopladores: Simplificado de Estado Estacionario, Simplificado y Generalizado. Los valores de las consignas fueron 60 °C para la temperatura del caudal a la salida de los tubos, y 41 °C para la temperatura del caudal a la salida de la carcasa; las variables manipuladas fueron los caudales de entrada a los tubos y la carcasa, gracias a los porcentajes de apertura de las válvulas correspondientes. Se emplearon controladores PI que fueron sintonizados con la aplicación del diseño IMC. De los resultados se pudo apreciar que el desacople simplificado fue el que más disminuyó el efecto del acoplamiento. ABSTRACT: This document describes the validation of linear multivariable control designs in a heat exchanger under virtual environment using Hysys, where the interest was focused on the analysis of the different responses of MIMO system when regulatory control was done with different decouplers and without decoupler. Three types of decoupling were used: Steady-State Simplified, Simplified and Generalized. The values of the set-points were 60 °C for the flow temperature at the outlet of the tubes, and 41 °C for the flow temperature at the outlet of the shell; the manipulated variables were the flows into the tubes and the shell, because percentages of opening the corresponding valves. PI controllers were tuned by IMC design and used to regulate the temperatures. By comparing the outcomes, it´s evident that Simplified Decoupling is the best to reduce the effect of the disturbance by coupling. Bibliografía: página 25 Artículo revisado por pares. 2017-07-27T16:39:24Z 2017-07-27T16:39:24Z 2017-06-13 Artículo de revista http://purl.org/coar/resource_type/c_6501 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Text https://purl.org/redcol/resource_type/ART http://purl.org/coar/version/c_970fb48d4fbd8a85 Ricardo Barrera, J. F. y Barrios Urueña, E. (2017). Control multivariable lineal con desacoples en un intercambiador de calor. Revista Ingeniería, Investigación y Desarrollo, 17(1), 17-25. DOI: https://doi.org/10.19053/1900771X.v17.n1.2017.5428. http://repositorio.uptc.edu.co/handle/001/1787 1900-771X En línea: 2422-4324 https://repositorio.uptc.edu.co/handle/001/1787 10.19053/1900771X.v17.n1.2017.5428 spa F. Delatore, F. Leonardi, L. Novazzi, J. Da Cruz, Multivariable H-Infinity model matching control of a heat exchanger network (HEN) with bypasses. IEEE Xplore Digital Library, 2011. DOI: https://doi. org/10.1109/icca.2011.6138094. J. Rico, M. Gil-Martinez, Multivariable QFT robust control of a heat exchanger. IEEE Xplore Digital Library, 2011. DOI: https://doi.org/10.1109/ med.2011.5983125. A. Vasičkaninová, M. Bakošová, Control of a heat exchanger using Takagi-Sugeno fuzzy model. IEEE Xplore Digital Library, 2014. DOI: https://doi. org/10.1109/carpathiancc.2014.6843684. Z. Zidane, M. Lafkih, M. Ramzi, Adaptive Generalized Predictive Control of a heat exchanger pilot plant. IEEE Xplore Digital Library, 2011. DOI: https://doi.org/10.1109/icmcs.2011.5945715. D. Kajzr, M. Diblík, L. Beran, L. Hubka, The possibilities for design and implementation of multivariate control for a level control in a double tank process. IEEE Xplore Digital Library, 2016. DOI: https://doi. org/10.1109/carpathiancc.2016.7501112. J. Nandong, Synthesis of multivariable PID controllers via inter-communicative decentralized multiscale control for TITO processes. IEEE Xplore Digital Library, 2015. DOI: https://doi.org/10.1109/ ascc.2015.7244403. C. Fu, W. Tan, Partially decentralized control based on IMC for a benchmark boiler. IEEE Xplore Digital Library, 2015. DOI: https://doi.org/10.1109/ ccdc.2015.7161662. M. Sirsat, B. Parvat, C. Kadu, Design of decentralized PI controller for two-input, two-output processes. IEEE Xplore Digital Library, 2015. DOI: https://doi.org/10.1109/icesa.2015.7503390. S. Datta, U. Nath, C. Dey, Design and implementation of decentralized IMC-PI controllers for real time coupled tank process. IEEE Xplore Digital Library, 2015. DOI: https://doi.org/10.1049/ cp.2015.1613. Revista Ingeniería, Investigación y Desarrollo;Vol. 17, núm 1 (2017) Copyright (c) 2017 Ingeniería, Investigación y Desarrollo https://creativecommons.org/licenses/by-nc/4.0/ info:eu-repo/semantics/openAccess Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0) http://purl.org/coar/access_right/c_abf2 application/pdf application/pdf Universidad Pedagógica y Tecnológica de Colombia http://revistas.uptc.edu.co/index.php/ingenieria_sogamoso/article/view/5428 |
spellingShingle | Sistemas de control lineal Sistemas de control multivaribales Control de procesos industriales Microprocesadores - Diseño Controladores PI Ricardo Barrera,Jaime Freddy Barrios Urueña, Edgar Control multivariable lineal con desacoples en un intercambiador de calor |
title | Control multivariable lineal con desacoples en un intercambiador de calor |
title_full | Control multivariable lineal con desacoples en un intercambiador de calor |
title_fullStr | Control multivariable lineal con desacoples en un intercambiador de calor |
title_full_unstemmed | Control multivariable lineal con desacoples en un intercambiador de calor |
title_short | Control multivariable lineal con desacoples en un intercambiador de calor |
title_sort | control multivariable lineal con desacoples en un intercambiador de calor |
topic | Sistemas de control lineal Sistemas de control multivaribales Control de procesos industriales Microprocesadores - Diseño Controladores PI |
url | https://repositorio.uptc.edu.co/handle/001/1787 |
work_keys_str_mv | AT ricardobarrerajaimefreddy controlmultivariablelinealcondesacoplesenunintercambiadordecalor AT barriosuruenaedgar controlmultivariablelinealcondesacoplesenunintercambiadordecalor AT ricardobarrerajaimefreddy linearmultivariablecontrolwithdecouplinginaheatexchanger AT barriosuruenaedgar linearmultivariablecontrolwithdecouplinginaheatexchanger |